Related Experiment Video
Updated: Jun 8, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Handcarried echocardiography to assess hemodynamics in acute decompensated heart failure
Sascha N Goonewardena1, Kirk T Spencer
1University of Michigan, Ann Arbor, MI 48109, USA.
Abstract:
Heart failure is a major source of cardiovascular morbidity, including acute decompensations requiring hospitalization. Because most therapeutic interventions in acute heart failure target optimization of cardiac output and volume status, accurate assessment of these parameters at the point of care is critical to guide management. However, physician bedside assessments of left ventricular (LV) function and volume status have limited accuracy. Traditional echocardiographic platforms, while useful for assessing ventricular and valvular function and volume status, have limitations for bedside use or frequent serial evaluation. Handcarried cardiac ultrasound devices, with their substantially lower costs, portability, and ease of use, circumvent many of the limitations of traditional echocardiographic platforms. The diagnostic capabilities of handcarried devices provide the opportunity for ultrasound assessment of LV function and serial bedside evaluation of volume status in patients with acutely decompensated heart failure.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Dysrhythmias V: Evaluating Dysrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...