Related Experiment Video
Updated: Sep 12, 2026

Laser Capture Microdissection of Mammalian Tissue
Published on: October 1, 2007
Comparison of diagnostic accuracy and interpretation times for a standard and an advanced 3D visualisation technique
Thomas Mang1, Frank T Kolligs, Claus Schaefer
1Department of Radiology, Medical University of Vienna, Waehringer Guertel, 18-20, 1090, Vienna, Austria. thomas.mang@meduniwien.ac.at
Objective:
To compare the diagnostic accuracy of a standard bi-directional, three-dimensional (3D) CT colonography (CTC) fly-through (standard view, SV) with a unidirectional, 3D unfolding technique (panoramic view, PV).
Methods:
150 consecutive endoscopically-validated CTC patient datasets were retrospectively reviewed twice by two expert radiologists: first, with bidirectional SV, second, after 6-15 months, with unidirectional PV. Per-polyp sensitivities, percentage of visualised colonic mucosa, and reading times were calculated for both 3D visualisations. Results were tested for statistical significance by equivalence analysis for paired proportions and Student's paired t-test.
Results:
In 81 patients, 236 polyps (101 adenomas, 135 non-adenomas) were detected. Sensitivities for polyps ≤5 mm, 6-9 mm and ≥10 mm were 60.1% (113/188), 92.9% (26/28) and 95.0% (19/20) with bidirectional SV, and 60.6% (114/188), 96.4% (27/28) and 95.0% (19/20) with unidirectional PV. Overall sensitivity for adenomas was 86.1% and 84.2% for SV and PV. Both methods provided equivalent polyp detection, with an equivalence limit set at 5%. PV and SV visualised 98.9 ± 1.1% (97.0-99.9%) and 96.2 ± 2.3% (91.4-98.8%) of the colonic mucosa (p > 0.05). Mean interpretation time decreased from 14.6 ± 2.5 (9.2-22.8) minutes with SV to 7.5 ± 3.2 (5.0-14.4) using PV (p < 0.0001).
Conclusion:
3D CTC interpretation using unidirectional PV is equally as accurate, but significantly faster than an interpretation based on bidirectional SV.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography