Related Experiment Video
Updated: Jun 8, 2026

A Porcine Model of Acute Respiratory Failure with a Continuous Infusion of Oleic Acid
Published on: March 8, 2024
Unexpectedly low pulse oximetry measurements associated with variant hemoglobins: a systematic review
Madeleine Verhovsek1, Matthew P A Henderson, Gerard Cox
1Section of Hematology and Oncology, Department of Medicine, Boston University School of Medicine, Boston, MA 02118, USA. verhovm@mcmaster.ca
Abstract:
Pulse oximetry estimates arterial blood oxygen saturation based on light absorbance of oxy- and deoxy-hemoglobin at 660 and 940 nm wavelengths. Patients with unexpectedly low SpO₂ often undergo cardio-pulmonary testing to ascertain the cause of their hypoxemia. However, in a subset of patients, a variant hemoglobin is responsible for low SpO₂ measurements. The extent of this problem is unclear. We performed a systematic literature review for reports of low SpO₂ associated with variant hemoglobins. We also reviewed unpublished cases from an academic hemoglobin diagnostic reference laboratory. Twenty-five publications and four unpublished cases were identified, representing 45 patients with low SpO₂ and confirmed variant hemoglobin. Fifty-seven family members of patients had confirmed or suspected variant hemoglobin. Three low oxygen affinity variant hemoglobins had concordantly low SpO₂ and SaO₂. Eleven variant hemoglobins were associated with unexpectedly low SpO₂ measurements but normal SaO₂. Hemoglobin light absorbance testing was reported in three cases, all of which showed abnormal absorption spectra between 600 and 900 nm. Seven other variant hemoglobins had decreased SpO₂, with unreported or uncertain SaO₂. Twenty-one variant hemoglobins were found to be associated with low SpO₂. Most variant hemoglobins were associated with spuriously low SpO₂. Abnormal absorption spectra explain the discrepancy between SpO₂ and SaO(2) for some variants. The differential diagnosis of possible variant hemoglobin ought to be considered in asymptomatic patients found to have unexpectedly low SpO₂. The correct diagnosis will help to spare patients from unnecessary investigations and anxiety.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Measurement of Blood Pressure
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: