Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling01:26

Influence of Earth's Curvature and Atmospheric Refraction on Leveling

During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Errors in Global Positioning System01:26

Errors in Global Positioning System

Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...
Errors and Mistakes in Surveying01:19

Errors and Mistakes in Surveying

Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of attention,...
Photoreceptors and Visual Pathways01:22

Photoreceptors and Visual Pathways

At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category, whereas...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Contact lens-related complications in austere conditions among military personnel: a systematic review.

BMJ military health·2023
Same author

Retinal blood flow in critical illness and systemic disease: a review.

Annals of intensive care·2020
Same author

Detection of Papilloedema Study (DOPS): rates of false positive papilloedema in the community.

Eye (London, England)·2019
Same author

Differing presenting features of idiopathic intracranial hypertension in the UK and US.

Eye (London, England)·2019
Same author

Management of ocular trauma by maxillofacial surgeons at the Role 3, ISAF Hospital Kandahar over a 21 month period.

Journal of the Royal Army Medical Corps·2012
Same author

Ophthalmic injuries in British Armed Forces in Iraq and Afghanistan.

Eye (London, England)·2010
Same journal

A tribute to the <i>Journal of the Royal Army Medical Corps</i>.

Journal of the Royal Army Medical Corps·2019
Same journal

Towards the future: The final issue of the journal of the Royal Army Medical Corps 1903-2019.

Journal of the Royal Army Medical Corps·2019
Same journal

Interests and concerns of the Army Medical Services as reflected by the publications in the <i>Journal of the Royal Army Medical Corps</i> 1903-2019.

Journal of the Royal Army Medical Corps·2019
Same journal

Dispatched from the Editor in Chief: does the impact factor have any real relevance to our military health journal?

Journal of the Royal Army Medical Corps·2019
Same journal

Highlights of the edition: the military medical ethics special issue.

Journal of the Royal Army Medical Corps·2019
Same journal

Aeromedical evacuation in the humanitarian and disaster relief environment of Op RUMAN.

Journal of the Royal Army Medical Corps·2019
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
05:14

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

Published on: September 16, 2025

Refractive errors in the UK Armed Forces

R J Blanch, R A H Scott

    Journal of the Royal Army Medical Corps
    |October 6, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
    07:06

    Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

    Published on: March 29, 2022

    Related Experiment Videos

    Last Updated: Jun 8, 2026

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
    05:14

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

    Published on: September 16, 2025

    Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
    07:06

    Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

    Published on: March 29, 2022