Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Learning curve for Doppler measurement of fetal modified myocardial performance index
R Cruz-Martinez1, F Figueras, J J Jaramillo
1Department of Maternal-Fetal Medicine, University of Barcelona, Barcelona, Spain.
Objective:
To assess the learning curve for measurement of the fetal modified myocardial performance index (MPI).
Methods:
Three trainees with the theoretical knowledge of but without prior experience in performing MPI measurement were selected. Each trainee and one experienced examiner measured MPI in a cohort of 90 consecutive fetuses. The average difference between the three trainees and the expert in the MPI measurements was calculated; a difference below 10% was considered to indicate an accurate measurement. Individual and averaged learning curves were delineated using cumulative sum analysis (CUSUM).
Results:
The gestational age at evaluation ranged from 20 + 4 to 41 + 4 (mean, 33 + 3) weeks. The CUSUM plots demonstrated that, on average, competence in performing fetal MPI measurement was achieved by 65 cases. The average number of attempts to achieve competence were 42, 77 and 83 for the ejection time, isovolumetric contraction time and isovolumetric relaxation time, respectively.
Conclusions:
Evaluation of fetal MPI by an inexperienced trainee requires on average 65 measurements to achieve competence.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse