Related Experiment Video
Updated: Jun 8, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Arterial stiffness using radial arterial waveforms measured at the wrist as an indicator of diabetic control in the
Hsien-Tsai Wu1, Chun-Ho Lee, An-Bang Liu
1Department of Electrical Engineering, National Dong Hwa University, Hualien 97401, Taiwan. hsientsaiwu@gmail.com
Abstract:
Although current technique of photoplethysmography (PPG) is a popular noninvasive method of waveform contour analysis in assessing arterial stiffness, data obtained are frequently affected by various environmental and physiological factors. We proposed an easily operable air pressure sensing system (APSS) for radial arterial signal capturing. Totally, 108 subjects (young, the aged with or without diabetes) were recruited from July 2009 to May 2010. Arterial waveform signals from the wrist were obtained and analyzed using Hilbert-Huang transformation (HHT). Through ensemble empirical mode decomposition (EEMD), the signals were decomposed into eight intrinsic mode functions (IMF1-8) of which IMF5 was found to be the desired signal with a discernible diastolic peak. The results showed significant differences in reflection index (RI) and stiffness index (SI) from the young subjects and those from the aged participants with or without diabetes. Significant differences in RI and SI were also noted between subjects with well-controlled diabetes and those without. Good reproducibility and correlation were demonstrated. In conclusion, the present study proposed the application of radial arterial signal capturing subsystem and HHT in acquiring more reliable data on RI and SI compared with the conventional PPG method.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure in the Leg
Preparation:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
