Occupational exposure to electric fields and induced currents associated with 400kV substation tasks from different

Leena H Korpinen1, Jarmo A Elovaara, Harri A Kuisti

  • 1Tampere University of Technology, Finland. leena.korpinen@tut.fi

Bioelectromagnetics
|October 7, 2010
PubMed

Related Concept Videos

Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Induced Electric Fields01:23

Induced Electric Fields

The fact that emfs are induced in circuits implies that work is being done on the conduction electrons in the wires. What can possibly be the source of this work? We know that it’s neither a battery nor a magnetic field, as a battery does not have to be present in a circuit where current is induced, and magnetic fields never do any work on moving charges. The source of the work is in fact an electric field that is induced in the wires. For example, if a stationary conductor is placed in a...
Electric Flux01:15

Electric Flux

The concept of flux describes how much of something goes through a given area. More formally, it is the dot product of a vector field within an area. For a better understanding, consider an open rectangular surface with a small area that is placed in a uniform electric field. The larger the area, the more field lines go through it and, hence, the greater the flux; similarly, the stronger the electric field (represented by a greater density of lines), the greater the flux. On the other hand, if...
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Equipotential Surfaces and Field Lines01:29

Equipotential Surfaces and Field Lines

Electric potential can be pictorially represented as a three-dimensional surface. On such a surface, the electric potential is constant everywhere. The equipotential surface is always perpendicular to the electric field lines, and while it is three-dimensional, it can be treated as an equipotential line in a two-dimensional case. These equipotential lines are also always perpendicular to electric field lines. The term equipotential is often used as a noun, referring to an equipotential line or...