Computational fluid dynamic analysis of flow velocity waveform notching in umbilical arteries
Andrés E Tejada-Martínez1, Christian J Borberg, Resmi Venugopal
1Department of Civil and Environmental Engineering, University of South Florida, Tampa, Florida, USA. aetejada@usf.edu
Abstract:
Umbilical artery Doppler velocimetry waveform notching has long been associated with umbilical cord abnormalities, such as distortion, torsion, and/or compression (i.e., constriction). The physical mechanism by which the notching occurs has not been elucidated. Flow velocity waveforms (FVWs) from two-dimensional pulsatile flows in a constricted channel approximating a compressed umbilical cord are analyzed, leading to a clear relationship between the notching and the constriction. Two flows with an asymmetric, semi-elliptical constriction are computed using a stabilized finite-element method. In one case, the constriction blocks 75% of the flow passage, and in the other the constriction blocks 85%. Channel width and prescribed flow rates at the channel inflow are consistent with typical cord diameters and flow rates reported in the literature. Computational results indicate that waveform notching is caused by flow separation induced by the constriction, giving rise to a vortex (core) wave and associated eddies. Notching in FVWs based on centerline velocity (centerline FVW) is directly related to the passage of an eddy over the point of measurement on the centerline. Notching in FVWs based on maximum cross-sectional velocity (envelope FVW) is directly related to acceleration and deceleration of the fluid along the vortex wave. Results show that notching in envelope FVW is not present in flows with less than a 75% constriction. Furthermore, notching disappears as the vortex wave is attenuated at distances downstream of the constriction. In the flows with 75 and 85% constriction, notching of the envelope FVW disappears at ∼3.8 and ∼4.3 cm (respectively) downstream of the constriction. These results are of significant medical importance, given that envelope FVW is typically measured by commercial Doppler systems.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Related Concept Videos
Couette Flow
Applications of Integration to Find Blood Flow
Urodynamic Studies: Uroflowmetry
Bernoulli's Equation for Flow Along a Streamline
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...
Steady, Laminar Flow Between Parallel Plates