Differences in blood pressure and vascular responses associated with ambient fine particulate matter exposures measured at the personal versus community level
Related Experiment Video
Updated: Jun 8, 2026

Fundus Photography as a Convenient Tool to Study Microvascular Responses to Cardiovascular Disease Risk Factors in Epidemiological Studies
Published on: October 22, 2014
Robert D Brook1, Robert L Bard, Richard T Burnett
1Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA. robdbrok@umich.edu
Background:
Higher ambient fine particulate matter (PM₂.₅) levels can be associated with increased blood pressure and vascular dysfunction.
Objectives:
To determine the differential effects on blood pressure and vascular function of daily changes in community ambient- versus personal-level PM₂.₅ measurements.
Methods:
Cardiovascular outcomes included vascular tone and function and blood pressure measured in 65 non-smoking subjects. PM₂.₅ exposure metrics included 24 h integrated personal- (by vest monitors) and community-based ambient levels measured for up to 5 consecutive days (357 observations). Associations between community- and personal-level PM₂.₅ exposures with alterations in cardiovascular outcomes were assessed by linear mixed models.
Results:
Mean daily personal and community measures of PM₂.₅ were 21.9±24.8 and 15.4±7.5 μg/m³, respectively. Community PM₂.₅ levels were not associated with cardiovascular outcomes. However, a 10 μg/m³ increase in total personal-level PM₂.₅ exposure (TPE) was associated with systolic blood pressure elevation (+1.41 mm Hg; lag day 1, p<0.001) and trends towards vasoconstriction in subsets of individuals (0.08 mm; lag day 2 among subjects with low secondhand smoke exposure, p=0.07). TPE and secondhand smoke were associated with elevated systolic blood pressure on lag day 1. Flow-mediated dilatation was not associated with any exposure.
Conclusions:
Exposure to higher personal-level PM₂.₅ during routine daily activity measured with low-bias and minimally-confounded personal monitors was associated with modest increases in systolic blood pressure and trends towards arterial vasoconstriction. Comparable elevations in community PM₂.₅ levels were not related to these outcomes, suggesting that specific components within personal and background ambient PM₂.₅ may elicit differing cardiovascular responses.
Related Concept Videos
Measurement of Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
