Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Investigation of LE-LIBS feasibility for detection of H, He, and O in high vacuum using geological samples.

Optics letters·2025
Same author

Fringe formation in multiaperture speckle shear interferometry.

Applied optics·2010
Same author

Multiple-beam lateral shear interferometry for optical testing.

Applied optics·2010
Same author

Modified double-wedge-plate shearing interferometer for collimation testing.

Applied optics·2010
Same author

Multiple-beam wedge-plate shear interferometer for collimation testing.

Applied optics·2010
Same author

Real-time image processing with a cat conjugator.

Applied optics·2010
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

Collimation testing with linear dual-field, spiral, and evolute gratings: a comparative study.

K V Sriram, M P Kothiyal, R S Sirohi

    Applied Optics
    |October 14, 2010
    PubMed
    Summary
    This summary is machine-generated.

    This study compares linear dual-field, spiral, and evolute gratings for collimation testing using Talbot interferometry, evaluating their performance in optical metrology applications.

    More Related Videos

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
    07:22

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

    Published on: February 3, 2023

    Related Experiment Videos

    Last Updated: Jun 8, 2026

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
    10:39

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

    Published on: October 11, 2016

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
    07:22

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

    Published on: February 3, 2023

    Area of Science:

    • Optics and Metrology
    • Optical Engineering

    Background:

    • Talbot interferometry is a key technique for optical testing.
    • Grating performance directly impacts measurement accuracy.

    Purpose of the Study:

    • To comparatively evaluate linear dual-field, spiral, and evolute gratings.
    • To determine optimal grating types for collimation testing.

    Main Methods:

    • Performance analysis of different grating types.
    • Utilizing Talbot interferometry for collimation testing.

    Main Results:

    • Performance metrics for each grating type were assessed.
    • Comparative data on grating suitability for collimation testing was generated.

    Conclusions:

    • The study provides insights into grating selection for optical metrology.
    • Findings aid in optimizing collimation testing procedures.