Related Experiment Video
Updated: Jun 8, 2026

Detection of Viruses from Bioaerosols Using Anion Exchange Resin
Published on: August 22, 2018
Are laptop ventilation-blowers a potential source of nosocomial infections for patients?
Katja Siegmund1, Nils Hübner, Claus-Dieter Heidecke
1Institute of Hygiene and Environmental Medicine, Ernst Moritz Arndt University, Greifswald, Germany.
Abstract:
Inadequately performed hand hygiene and non-disinfected surfaces are two reasons why the keys and mouse-buttons of laptops could be sources of microbial contamination resulting consequently in indirect transmission of potential pathogens and nosocomial infections. Until now the question has not been addressed whether the ventilation-blowers in laptops are actually responsible for the spreading of nosocomial pathogens. Therefore, an investigational experimental model was developed which was capable of differentiating between the microorganisms originating from the external surfaces of the laptop, and from those being blown out via the ventilation-blower duct. Culture samples were taken at the site of the external exhaust vent and temperature controls were collected through the use of a thermo-camera at the site of the blower exhaust vent as well as from surfaces which were directly exposed to the cooling ventilation air projected by the laptop. Control of 20 laptops yielded no evidence of microbial emission originating from the internal compartment following switching-on of the ventilation blower. Cultures obtained at the site of the blower exhaust vent also showed no evidence of nosocomial potential. High internal temperatures on the inner surfaces of the laptops (up to 73°C) as well as those documented at the site of the blower exhaust vent (up to 56°C) might be responsible for these findings.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Pneumonia I: Introduction
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
