Discrimination of green arabica and Robusta coffee beans by Raman spectroscopy
Anke Keidel1, David von Stetten, Carla Rodrigues
1Technische Universität Berlin, Institut für Chemie, Sekr. PC14, Strasse des 17 Juni 135, D-10623 Berlin, Germany.
Abstract:
This paper presents an approach that may be applied as an accurate and rapid tool for classifying coffee beans on the basis of the specific kahweol content. Using Fourier-transform Raman spectroscopy with 1064 nm excitation it is possible to monitor the characteristic Raman bands of kahweol in green coffee beans without chemical and physical processing of the beans. The procedure was optimized on the basis of 83 and 125 measurements of whole and ground beans, respectively, using coffee samples of two different species, Coffea arabica L. and Coffea canephora L. (var. Robusta), and different origins (Asia, Africa, and South America). The relative contribution of the kahweol in individual beans can be determined quantitatively by means of a component analysis of the spectra, yielding a spectral kahweol index (σka) that is proportional to the relative content of kahweol in a coffee bean. The reproducibility of the spectroscopic measurement and analysis was found to be 3.5%. Individual beans of the same type and origin reveal a scattering of the σka values. Nevertheless, an unambiguous distinction between Arabica and Robusta samples is possible on the basis of single-bean measurements as the σka values are greater than and less than 10 for Arabica and Robusta coffees, respectively. Measurements of whole and ground beans afforded very similar results, despite the heterogeneous distribution of kahweol within a bean. Unlike conventional analytical techniques, the single-bean sensitivity of the present approach may also allow for a rapid detection of unwanted admixtures of low-value Robusta coffee to high-quality and more expensive Arabica coffee.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectroscopy of Aromatic Compounds
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
UV–Vis Spectroscopy: Beer–Lambert Law


