Multi-enzyme Screening Using a High-throughput Genetic Enzyme Screening System
Published on: August 8, 2016
Parallel electrophoretic analysis of segmented samples on chip for high-throughput determination of enzyme activities
Jian Pei1, Jing Nie, Robert T Kennedy
1Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, United States.
Abstract:
Capillary electrophoresis (CE) on microfabricated structures has achieved impressive sample throughput by combining fast separation speed and parallel operations. One obstacle to further increasing throughput has been lack of methods for loading and injecting individual samples at a rate that matches analysis speed. To address this issue, we have developed a microfluidic device in which samples stored as nanoliter volume plugs segmented by a fluorocarbon oil are introduced sequentially to an array of three electrophoresis channels. A microfluidic interface consisting of patterned surface chemistry and geometric restriction was used to extract samples from each segmented flow channel and transfer to the respective electrophoresis channel for separation. Fluorescence detection was achieved by imaging the chip using a fluorescence microscope equipped with a charge-coupled device. Characterization of the system shows that injection volume is controlled by sample plug volume, flow rate during introduction, and voltage applied to the electrophoresis channel. The system was tested for a GTPase assay. Peak area ratios of enzyme product and internal standard had 6% relative standard deviations. Cross-contamination between peaks was 7%. Throughput of 120 samples in 10 min was achieved. Further development of the system may allow application to high-throughput applications such as drug screening.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Instrumentation
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...