Related Experiment Video
Updated: Jun 8, 2026

04:36
Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
Leonardo Akaishi1, Rodrigo Vaz, Graziela Vilella
1Brasilia Ophthalmologic Hospital (HOB), SQSW 306, Bloco A, Apartment 105, Brasilia DF 70640-000, Brazil.
Journal of Ophthalmology
|October 19, 2010
Summary
The Tecnis ZM900 multifocal intraocular lens (IOL) provides excellent vision at all distances after cataract surgery. Most patients achieved spectacle independence with minimal photic phenomena, indicating high satisfaction.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Retinal Science
Background:
- Cataract surgery is a common procedure to restore vision.
- Multifocal intraocular lenses (IOLs) aim to provide clear vision at multiple distances.
- The Tecnis ZM900 is a new diffractive multifocal IOL designed for improved visual outcomes.
Purpose of the Study:
- To evaluate the visual performance of the Tecnis ZM900 multifocal IOL.
- To assess patient-reported outcomes, including photic phenomena and satisfaction.
- To determine the effectiveness of this IOL in eyes undergoing phacoemulsification.
Main Methods:
- Retrospective analysis of 2,500 eyes implanted with the Tecnis ZM900 IOL.
- Minimum 3-month follow-up period post-surgery.
- Assessment of uncorrected visual acuities (distance, intermediate, near) and subjective patient questionnaires.
Main Results:
- 85% of eyes achieved uncorrected distance visual acuity (UDVA) of 20/30 or better.
- 93.7% achieved J1 near visual acuity; 98% achieved J2 or better.
- 65% achieved J4 intermediate visual acuity; 82.8% achieved J5 or better.
- Severe glare and halos reported by only 6.1% and 2.12% of patients, respectively.
- 97% reported spectacle independence; 88% were satisfied and would choose the IOL again.
Conclusions:
- The Tecnis ZM900 diffractive multifocal IOL delivers excellent visual outcomes across near, intermediate, and distance ranges.
- High rates of spectacle independence and patient satisfaction, coupled with low photic phenomena, make it a strong option for cataract patients.
- The IOL demonstrates a favorable safety profile, with only 5% requiring enhancement and no lens exchanges.