Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit

P J Gilvin1, C A Perks

  • 1Health Protection Agency, Chilton, Didcot, Oxon OX11 0RQ, UK.

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...
Dosage Regimens: Partial Pharmacokinetic Parameters01:01

Dosage Regimens: Partial Pharmacokinetic Parameters

It is not uncommon for complete drug pharmacokinetic profiles to remain elusive in pharmacokinetics. This necessitates certain educated assumptions by pharmacokineticists to determine appropriate dosage regimens without comprehensive pharmacokinetic data from animal or human studies. One prevalent assumption is setting the bioavailability factor, denoted as F, to 1 or 100%. This assumption caters to the scenario where a drug doesn't achieve full systemic absorption, resulting in the patient...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
Dose Response Curve: Conventional Versus Nonmonotonic01:21

Dose Response Curve: Conventional Versus Nonmonotonic

The correlation between a drug's dosage and its impact on a biological system is a cornerstone of pharmacology and toxicology. Conventional dose–response curves, which include graded and quantal relationships, are key to this understanding. Graded dose–response curves depict the spectrum of a biological reaction to different doses within an individual, indicating that as the drug dosage increases, so does the intensity of the response. On the other hand, quantal dose–response relationships...