Related Experiment Video
Updated: Jun 7, 2026

09:33
A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Measuring flow-mediated dilation through transverse and longitudinal imaging: comparison and validation of methods
Marianne J Stroz1, Aaron Fenster
1Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A5K8, Canada. mstroz@imaging.robarts.ca
Physics in Medicine and Biology
|October 21, 2010
Summary
Three-dimensional ultrasound imaging (3DUS) of the brachial artery assessed flow-mediated dilation (FMD) reproducibility. Transverse imaging and semi-automated vessel area measurement (TISA) offer the best balance of precision and reproducibility for FMD assessment.
Area of Science:
- Vascular Ultrasound
- Cardiovascular Imaging
- Biomedical Engineering
Background:
- Flow-mediated dilation (FMD) is a key indicator of endothelial function.
- Accurate and reproducible measurement of FMD is crucial for clinical and research applications.
- Traditional methods using longitudinal ultrasound images have limitations in precision and reproducibility.
Purpose of the Study:
- To compare the reproducibility and precision of different three-dimensional ultrasound imaging (3DUS) techniques for quantifying brachial artery FMD.
- To evaluate manual (TIMA) and semi-automated (TISA) vessel area measurements, and diameter measurements (TID) in transverse planes.
- To compare these transverse plane methods against the traditional longitudinal diameter measurement (LID).
Main Methods:
- 3DUS of the brachial artery was performed at baseline.
- Transverse images were analyzed using TIMA, TISA, and TID.
- Inter- and intra-observer variability, and transducer repositioning variability were assessed and compared to LID.
Main Results:
- All methods showed similar inter-observer variability.
- TID demonstrated the highest intra-observer precision (COV(intra)=0.31%, Δd(intra)=0.87%), while LID performed poorest (COV(intra)=0.57%, Δd(intra)=1.59%).
- TIMA (COV(rep)=2.35%, ΔFMD=6.52%) and TISA showed superior reproducibility over time compared to TID (COV(rep)=5.37%, ΔFMD=14.89%).
Conclusions:
- Transverse imaging planes offer equal or less variability than longitudinal planes for FMD assessment.
- TISA is recommended as the method of choice for FMD assessment due to its speed, simplicity, and high reproducibility, comparable to TIMA.
- Semi-automated measurement of vessel area in the transverse plane using 3DUS provides a reproducible and precise method for FMD quantification.

