Placebo effect and adaptation to noninvasive monitoring of BP
M Antivalle1, S Lattuada, A Salvaggio
1Clinica Medica Università degli Studi, Ospedale L. Sacco, Milano, Italy.
Abstract:
Three 24 h ambulatory monitorings of BP were performed at two-week intervals in 21 untreated hypertensives (mean age 38 +/- 10 yrs, 13 males and 9 females). After the first baseline monitoring, the patients were randomised, according to a cross-over design, to one of the following sequences: no therapy to placebo or placebo to no therapy. At the end of each period, noninvasive ambulatory monitoring was performed. Mean +/- SE 24 h systolic (SBP) and diastolic (DBP) pressures recorded at the first monitoring were 129.2 +/- 3.5 mmHg and 81.7 +/- 2.3 mmHg respectively. At the second and third monitorings, mean 24 h BP differences versus baseline levels were -2.9 +/- 1.8 and -4.7 +/- 1.7 mmHg for SBP, and -2.0 +/- 1.1 and -2.7 +/- 1.5 mmHg for DBP. Both SBP and DBP differences at repeated monitorings were significant by analysis of variance (P less than 0.05). No significant effects on BP of treatment sequence or of placebo administration were found. Analysis of covariance showed a significant relationship between initial 24 h BP and subsequent mean 24 h BP differences (SBP: beta = -0.260, DBP: beta = -0.124). ANOVA performed on waking and sleeping BP separately showed the observed differences to be significant only during waking hours. Regression analysis showed that the decrease in 24 h BP at repeated monitorings was significantly related to the extent of 'white coat'-induced BP increase only for DBP (P = 0.022). For both 24 h SBP and DBP, however, a negative correlation between the alarm reaction to the presence of the physician and 24 h BP decrease at repeated monitorings was observed. It is concluded that noninvasive ambulatory monitoring is subject to adaptative phenomena but not to placebo effect. Factors influencing the defence reactions to manual measurements and to ambulatory monitoring might be partly different.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Related Concept Videos
The Placebo Effect
Blind Procedures
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure