Related Experiment Video
Updated: Jun 7, 2026

12:14
The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
Published on: August 12, 2013
Line-shape studies for single- and triple-pass Fabry-Perot interferometer systems
Applied Optics
|October 22, 2010
Abstract:
To test the model developed in the preceding paper [Appl. Opt. 34, this issue (1994)] regarding the line shape produced by a Fabry-Perot interferometer system in a multipass mode, we have used three Lorentzian line shapes formed in scattering processes and subjected them to single and triple passes with some variation in the pinhole diameter. In most cases we find good agreement with the calculations with the only adjustable parameter being the single-pass contrast C(1). Where differences occur, plausible explanations are offered.