Related Experiment Video
Updated: Jun 7, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Truly stentless autologous pericardial aortic valve replacement: an alternative to standard aortic valve replacement
K M John Chan1, Shelley Rahman-Haley, Tarun K Mittal
1Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, Royal Brompton Hospital, London, United Kingdom. KMJChan@btopenworld.com
Objective:
The aim of this study was to determine the feasibility and durability of truly stentless aortic valve replacement using autologous pericardium sutured directly onto the aortic wall.
Methods:
Eleven patients (mean age, 55.9 years) requiring aortic valve replacement were recruited. A circular piece of pericardium about 8 cm in diameter was harvested and treated in 0.6% glutaraldehyde for 10 minutes. The aortic valve was excised and, with the use of specially designed instruments (CardioMend LLC, Santa Barbara, Calif), the sinotubular junction was sized and the pericardium was tailored to the required size and shape and then sutured directly onto the aortic wall. The reconstructed valve was assessed directly and by echocardiography at the end of the operation; it was assessed by echocardiography and cardiac magnetic resonance imaging at 6 months and yearly. Computed tomographic scan of the aortic valve to assess for valve calcification was performed at last follow-up.
Results:
Hospital mortality was 0%. Mean follow-up was 6.5 years (range, 5.3-7.5 years). Freedom from structural valve deterioration, thromboembolism, endocarditis and reoperation was 100%, 100%, 72.7%, and 63.6%, respectively. There were 4 reoperations at 4, 13, 15, and 46 months, 3 of them owing to endocarditis and 1 owing to technical failure noted at the time of surgery. The remaining 7 patients are alive and well with a mean New York Heart Association class of 1.3 and normally functioning aortic valves with no calcification.
Conclusions:
Truly stentless aortic valve replacement using autologous pericardium sutured directly onto the aortic wall is safe and feasible and has excellent durability up to 7.5 years with no calcification.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Related Concept Videos
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management