Related Experiment Video
Updated: Jun 7, 2026

06:36
Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Comparison between different interdental stripping methods and evaluation of abrasive strips: SEM analysis
Cristina Grippaudo1, Daniela Cancellieri, Maria E Grecolini
1Department of Orthodontics, Catholic University of Sacred Heart, Rome, Italy. cgrippaudo@rm.unicatt.it
Progress in Orthodontics
|October 27, 2010
Summary
Finishing procedures are crucial for smoothing enamel surfaces after mechanical stripping, with sealants recommended after air rotor stripping. Proper finishing minimizes enamel damage regardless of the abrasive strip used.
Area of Science:
- Dental materials science
- Conservative dentistry
- Surface analysis
Background:
- Dental enamel stripping is used to correct tooth shape and alignment.
- Different mechanical and chemical methods exist, each potentially affecting enamel surface integrity.
- Surface irregularities can impact plaque accumulation and caries risk.
Purpose of the Study:
- To compare the surface irregularities caused by various mechanical (strips, burs) and chemical (orthophosphoric acid) stripping methods.
- To evaluate the effects of finishing procedures (polishing strips) and sealant application on stripped enamel surfaces.
- To determine the optimal stripping and finishing protocol for achieving the smoothest enamel surface and to analyze abrasive strip wear.
Main Methods:
- Scanning electron microscopy (SEM) was used to examine 160 proximal enamel surfaces from 80 sound molar teeth.
- Teeth were divided into a control group and five experimental groups based on stripping method (mechanical and chemical).
- Experimental groups were further subdivided to assess finishing procedures or sealant application.
Main Results:
- Finishing stages significantly reduced groove depth and number created by stripping.
- Sealant application after air rotor stripping improved surface smoothness.
- Combinations of mechanical and chemical stripping yielded unsatisfactory results.
- SEM analysis revealed varying degrees of wear among different abrasive strip types.
Conclusions:
- Enamel damage is minimized when finishing procedures are consistently applied, irrespective of the abrasive strip type.
- Sealants are advisable after air rotor stripping to enhance surface smoothness, though clinical application may be limited.
- The study highlights the importance of finishing protocols in managing enamel surface morphology after stripping procedures.

