Related Experiment Video
Updated: Jun 7, 2026

Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Simultaneous spectrophotometric determination of atrazine and cyanazine by chemometric methods
1State Key Laboratory of Food Science and Technology, Nanchang University, 235, Nanjing East Road, Nanchang 330047, Jiangxi, China. gwzhang@ncu.edu.cn
Abstract:
A spectrophotometric method for the simultaneous determination of two herbicides, atrazine and cyanazine, is described for the first time based on their reaction with p-aminoacetophenone in the presence of pyridine in hydrochloric acid medium. The absorption spectra were measured in the wavelength range of 400-600 nm. The optimized method indicated that individual analytes followed Beer's law in the concentration ranges for atrazine and cyanazine were 0.2-3.5 mg L(-1) and 0.3-5.0 mg L(-1), and the limits of detection for atrazine and cyanazine were 0.099 and 0.15 mg L(-1), respectively. The original and first-derivative absorption spectra of the binary mixtures were performed as a pre-treatment on the calibration matrices prior to the application of chemometric models such as classical least squares (CLS), principal component regression (PCR), partial least squares (PLS). The analytical results obtained by using these chemometric methods were evaluated on the basis of percent relative prediction error and recovery. It was found that the application of PCR and PLS models for first-derivative absorbance data gave the satisfactory results. The proposed methods were successfully applied for the simultaneous determination of the two herbicides in several food samples.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Titrimetric Methods: Types and Commonly Used Strategies
Measuring Reaction Rates
