Related Experiment Video
Updated: Jun 7, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Quantitative analysis of acid-base disorders in patients with chronic respiratory failure in stable or unstable
Claude Guérin1, Pascale Nesme, Véronique Leray
1Service de Réanimation Médicale et d'Assistance Respiratoire, Hôpital de la Croix Rousse, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France. claude.guerin@chu-lyon.fr
Background:
The Stewart approach theorizes that plasma pH depends on P(aCO₂), the strong ion difference, and the plasma total concentration of non-volatile weak acids (A(tot)). The conventional approach measures standardized base excess, bicarbonate (HCO₃⁻), and the anion gap.
Objective:
To describe acid-base disorders with the Stewart approach and the conventional approach in patients with chronic respiratory failure.
Methods:
This was an observational prospective study in a medical intensive care unit and a pneumology ward of a university hospital. There were 128 patients included in the study, of which 14 had more than one admission, resulting in 145 admissions. These were allocated to 4 groups: stable respiratory condition and elevated HCO₃⁻ (Group 1, n = 23), stable respiratory condition and non-elevated HCO₃⁻ (Group 2, n = 41), unstable respiratory condition and elevated HCO₃⁻ (Group 3, n = 44), and unstable respiratory condition and non-elevated HCO₃⁻ (Group 4, n = 37). Elevated HCO₃⁻ was defined as ≥ 3 standard deviations higher than the mean value we found in 8 healthy volunteers. Measurements were taken on admission.
Results:
In groups 1, 2, 3, and 4, the respective mean ± SD values were: HCO₃⁻ 33 ± 3 mM, 26 ± 3 mM, 37 ± 4 mM, and 27 ± 3 mM (P < .001); strong ion difference 45 ± 3 mM, 38 ± 4 mM, 46 ± 4 mM, and 36 ± 4 mM (P < .001); and A(tot) 12 ± 1 mM, 12 ± 1 mM, 10 ± 1 mM, 10 ± 2 mM (P < .001). Non-respiratory disorders related to high strong ion difference were observed in 12% of patients with elevated HCO₃⁻, and in none of those with non-elevated HCO₃⁻ (P = .003). Non-respiratory disorders related to low strong ion difference were observed in 9% of patients with non-elevated HCO₃⁻, and in none of those with elevated HCO₃⁻ (P = .02). Hypoalbuminemia was common, especially in unstable patients (group 3, 66%; group 4, 65%). Normal standardized base excess (16%), HCO₃⁻ (28%), and anion gap (30%) values were common. The Stewart approach detected high effective strong ion difference in 13% of normal standardized base excess, and in 20% of normal anion gap corrected for albuminemia, and low effective strong ion difference in 22% of non-elevated HCO₃⁻.
Conclusions:
In patients with chronic respiratory failure the acid-base pattern is complex, metabolic alkalosis is present in some patients with elevated HCO₃⁻, and metabolic acidosis is present in some with non-elevated HCO₃⁻. The diagnostic performance of the Stewart approach was better than that of the conventional approach, even when corrected anion gap was taken into account.
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are produced, leading to a...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-III
Bronsted-Lowry Acids and Bases
