Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Adjusting a Traverse01:12

Adjusting a Traverse

In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling01:26

Influence of Earth's Curvature and Atmospheric Refraction on Leveling

During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The paraxial differential transfer coefficients of a lens system.

Journal of the Optical Society of America·2010
Same author

Control of welding fumes.

Bulletin of the Academy of Medicine, Toronto·2010
Same author

On the primary chromatic coefficients of a lens system.

Journal of the Optical Society of America·2010
See all related articles

Related Experiment Video

Updated: Jun 7, 2026

Video-rate Scanning Confocal Microscopy and Microendoscopy
14:10

Video-rate Scanning Confocal Microscopy and Microendoscopy

Published on: October 20, 2011

The trigonometrical correction of microscope objectives

F D CRUICKSHANK

    Journal of the Optical Society of America
    |October 29, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    Keywords:
    MICROSCOPY

    More Related Videos

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
    05:14

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

    Published on: September 16, 2025

    Bringing the Visible Universe into Focus with Robo-AO
    10:35

    Bringing the Visible Universe into Focus with Robo-AO

    Published on: February 12, 2013

    Related Experiment Videos

    Last Updated: Jun 7, 2026

    Video-rate Scanning Confocal Microscopy and Microendoscopy
    14:10

    Video-rate Scanning Confocal Microscopy and Microendoscopy

    Published on: October 20, 2011

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
    05:14

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

    Published on: September 16, 2025

    Bringing the Visible Universe into Focus with Robo-AO
    10:35

    Bringing the Visible Universe into Focus with Robo-AO

    Published on: February 12, 2013