Abstract:
Carotid-radial pulse wave velocity (CRPWV) can be measured rapidly using applanation tonometry and significantly higher values have been reported among patients with risk factors for vascular disease. Forearm blood flow responses to intrabrachial infusion of acetylcholine independently predict cardiovascular morbidity among hypertensive patients. We aimed to examine the relationship between CRPWV, a potentially informative, noninvasive measure and this more established parameter of arterial health. One hundred and fifteen mildly hypertensive individuals (67% men, mean (± SD) age 54 ± 8 years, mean (± SD) blood pressure (BP) 143 ± 16/83 ± 12 mmHg) were recruited from a weekly medical outpatient clinic. Each volunteer had CRPWV measured using sequential tonometry before forearm blood flow responses to intra-arterial, endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) vasodilators were assessed. There was a significant negative correlation between CRPWV and maximum forearm blood flow response to acetylcholine (r = -0.225, p = 0.016). This association remained significant in a multiple regression analysis (β = -0.213, p = 0.034). Mean arterial pressure and weight were additional independent predictors of CRPWV in this model. There was no such relationship between CRPWV and response to sodium nitroprusside (r = 0.088, p = 0.349). In patients with mild hypertension, a poor forearm blood flow response to acetylcholine independently predicted faster CRPWV, thus linking an established measure of microvascular endothelial function with a noninvasive index of conduit vessel stiffness.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse
The pulse serves as a clinical indicator...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Hypertension II: Pathophysiology
Hypertension and Regulation of Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...