Effectiveness of UV-C equipped vacuum at reducing culturable surface-bound microorganisms on carpets
Eric A Lutz1, Smita Sharma, Bruce Casto
1Division of Environmental Health Sciences, College of Public Health, The Ohio State University, Columbus, Ohio 43210, United States.
Abstract:
Carpets are both sinks and sources for exposure to chemicals, allergens, and microbes and consequently influence health, including asthma, allergies, and infectious diseases. Asthmatics, children, and the immune-compromised are particularly vulnerable to health risks resulting from exposure to carpet contaminants. To address this risk, a commercial upright vacuum cleaner with an ultraviolet germicidal lamp (λ=253.7 nm, UVC) has been developed for residential and commercial uses. However, its effectiveness in reducing microbial load on real-world carpets has not been previously demonstrated. Accordingly, the purpose of the current study was to evaluate the effectiveness of a UVC-equipped vacuum in reducing the carpet surface-bound microbial load. This was accomplished by comparing the carpet microbial surface load from pre- to post-treatment of 9 ft(2) in-use carpet sections under three treatment scenarios: 1) UVC alone (UV), 2) the beater-bar plus vacuum (BB+Vac), or 3) a combination of all three (COMB). Each treatment was two minutes in duration. Microbial surface loads were measured by pressing contact plates containing Sabourauds Dextrose agar onto the carpet surface. In-use carpets from three locations were tested in place. The treatment effect was evaluated at two levels. First, we considered the mean reduction in CFU from pre- to post-treatment for each 9 ft(2) carpet grid (n = 4 for each treatment). The second level considered each 1 ft(2) section using a paired analysis (n = 40 to 49 for each treatment). A total of 125 pre/post-sample pairs were collected across the three treatments. Results showed that all three treatments were associated with a reduction in carpet microbial load (p < 0.0001). The COMB yielded the largest reduction of 13 CFU/plate (87% reduction) and was approximately the sum of the individual effects of either UVC (6.6 CFU/plate, 60% reduction, p = 0.009) or BB+Vac (7.3 CFU/plate, 78% reduction, p < 0.0001). We therefore conclude that a UVC-equipped vacuum approximately doubles the unit's effectiveness in reducing surface-bound microbial load, thereby holding promise as a means for decreasing indoor infectious disease risk.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Antimicrobial Effectiveness
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature
Biological Methods for Microbial Control