Related Experiment Video
Updated: Jun 7, 2026

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
Published on: September 22, 2017
Conceptual design of the collection optics for the edge Thomson scattering system in ITER
1Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan. yatsuka.eiichi@jaea.go.jp
Abstract:
Neutron and gamma-ray irradiation complicates the design of the edge Thomson scattering (TS) system in ITER. The TS light is relayed through the relaying optics with labyrinth and fiber coupling optics. Electron density of 2×10(19) m(-3) is sufficient to measure T(e) and n(e) within a 10% and 5% margin of error, respectively, with a spatial resolution of 5 mm. This system can cover from 0.85 to 1 of the normalized minor radius. The time resolution is 10 ms, which is determined by the repetition rate of the laser device. A super-Gaussian is the ideal laser profile for the laser injection optics to avoid a breakdown of the filling gas used in density calibration through Raman scattering.
Related Concept Videos
Interference and Diffraction
Total Internal Reflection Fluorescence Microscopy