Threshold detection in the presence of atmospheric turbulence

Applied Optics
|November 2, 2010
PubMed

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Application of Linearization and Approximation01:29

Application of Linearization and Approximation

A drone flying through complex terrain often relies on more than one sensing method to estimate small changes in altitude. Along with direct measurements, air pressure provides a useful indirect indicator of vertical movement. Atmospheric pressure decreases as altitude increases, and this relationship is commonly described using an exponential model. Although accurate, converting pressure measurements into altitude values requires calculations that are too complex to perform repeatedly during...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Turbulent Flow01:24

Turbulent Flow

Turbulent flow is characterized by unpredictable fluctuations in velocity and pressure, which result in a chaotic fluid movement distinct from the orderly patterns of laminar flow. While laminar flow is governed by smooth, parallel layers with minimal mixing, turbulent flow exhibits highly irregular, three-dimensional patterns. This behavior arises due to instabilities in the fluid's velocity profile, and amplifies as the flow velocity increases. Minor disturbances, known as turbulent spots,...
Boundary Layer Characteristics01:18

Boundary Layer Characteristics

When a fluid encounters a solid surface, a boundary layer forms due to the interaction between the fluid's motion and the stationary surface. This phenomenon is characterized by a thin region adjacent to the surface where viscous forces dominate, influencing the fluid's velocity profile. The development of the boundary layer begins at the leading edge of the surface and evolves as the fluid moves downstream.As the fluid flows over the surface, friction between the fluid and the wall slows down...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...