Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The effects of K+ channel blockers on the spontaneous electrical and contractile activity in the proximal renal pelvis of the guinea pig.

The Journal of urology·1996
Same author

Interferon-gamma inhibits HIV-induced invasiveness of monocytes.

Journal of leukocyte biology·1995
Same author

Phosphorylation of Raf by ceramide-activated protein kinase.

Nature·1995
Same author

Cyclin D3 is essential for megakaryocytopoiesis.

Blood·1995
Same author

A P2X purinoceptor cDNA conferring a novel pharmacological profile.

FEBS letters·1995
Same author

Phosphorylation of nodulin 26 on serine 262 affects its voltage-sensitive channel activity in planar lipid bilayers.

The Journal of biological chemistry·1995

Related Experiment Video

Updated: Jun 7, 2026

Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities
09:12

Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities

Published on: April 22, 2013

Some developments for a unit magnification catadioptric optical system.

Y Zhang, Z Wang

    Applied Optics
    |November 2, 2010
    PubMed
    Summary
    This summary is machine-generated.

    Structural improvements enable the 1:1 Wynne-Dyson catadioptric system for deep-UV applications. This advancement allows for broad spectral bands and high numerical apertures in optical designs.

    More Related Videos

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

    Published on: August 4, 2018

    A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
    11:15

    A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

    Published on: May 30, 2016

    Related Experiment Videos

    Last Updated: Jun 7, 2026

    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities
    09:12

    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities

    Published on: April 22, 2013

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

    Published on: August 4, 2018

    A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
    11:15

    A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

    Published on: May 30, 2016

    Area of Science:

    • Optical Engineering
    • Deep-Ultraviolet Optics

    Background:

    • The Wynne-Dyson catadioptric system is a complex optical design.
    • Existing designs have limitations in spectral range and numerical aperture.

    Purpose of the Study:

    • To describe structural improvements for the 1:1 Wynne-Dyson catadioptric system.
    • To extend the system's usability into the deep-ultraviolet (UV) regime.

    Main Methods:

    • The study focuses on structural modifications to the existing optical system.
    • Analysis of optical performance under deep-UV conditions.

    Main Results:

    • The improved 1:1 Wynne-Dyson system is demonstrated to be functional in the deep-UV spectral range.
    • The modifications enable the use of broad spectral bands.
    • High numerical apertures are achievable with the enhanced system.

    Conclusions:

    • The structural enhancements significantly broaden the applicability of the 1:1 Wynne-Dyson catadioptric system.
    • The improved system is suitable for demanding optical applications requiring deep-UV performance, broad bandwidths, and high numerical apertures.