Simultaneous determination of Cu(II), Ni(II) and Zn(II) by peroxyoxalate chemiluminescence using Partial Least
J A Murillo Pulgarin1, L F García Bermejo, A Carrasquero
1Department of Analytical Chemistry and Foods Technology, University of Castilla-La Mancha, 13071 Ciudad Real, Spain. JoseAntonio.Murillo@uclm.es
Abstract:
It was found that the ions Cu(II), Ni(II) and Zn(II) can attenuate the peroxyoxalate chemiluminescence emission, which was used to develop an analytical procedure for the simultaneous determination of these ions in a stopped-flow system using Partial Least Square (PLS) calibration. Acetonitrile was used to dissolve TCPO and to prepare a mixture of fluorescein, H(2)O(2) and imidazole. These solutions were carried using two peristaltic pumps, while a third pump was employed to propel the aqueous solutions of the metallic ions. All solutions were mixed in the quartz cell of a Campsec CL detector connected to a personal computer to register the CL development using the Clarity software. Under the optimum operative conditions each ion produced a specific CL development with maximum intensities at 0.280 min for Zn(II), 0.307 min for Ni(II) and 0.327 min for Cu(II). The latter exhibited the highest inhibition effect. The experimental calibration set was composed of 16 sample solutions using a central design for three component mixtures with scaled values. The proposed method offers the advantages of simplicity, good precision and accuracy for the simultaneous determination of Ni(2+), Cu(2+) and Zn(2+) in water samples.
More Related Videos
09:22Synthesis and Performance Evaluations of ZnCoS/ZnCdS with Twin Crystal Structure for Multifunctional Redox Photocatalysis in Energy Applications
Published on: July 25, 2025
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Atomic Emission Spectroscopy: Lab
Complexometric Titration: Overview
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Instrumentation