Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques
Dingchang Zheng1, John N Amoore, Stephan Mieke
1Regional Medical Physics Department, Freeman Hospital, Newcastle University, Newcastle upon Tyne, UK. dingchang.zheng@ncl.ac.uk
Abstract:
Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained in 55 healthy subjects by two trained observers, and auscultatory MAP was estimated. Automated MAP was determined by six techniques from oscillometric cuff pressures recorded digitally and simultaneously during manual measurement. MAPs were derived from the peak and foot of the largest oscillometric pulse, and from time domain curves fitted to the sequence of oscillometric pulse amplitudes (4th order and three versions of the 6th order polynomial curve). The agreement between automated and auscultatory MAPs was assessed. Compared with the auscultatory MAP, the automated MAP from the baseline cuff pressure at the peak of the 6th order polynomial curve had the smallest mean paired difference (-1.0 mmHg), and smallest standard deviation of paired differences (3.7 mmHg). These values from the peak of the largest oscillometric pulse were -1.3 and 6.2 mmHg, respectively. Determining MAP from a model of the oscillometric pulse waveform had the smallest differences from the manual auscultatory technique.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure