Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T--initial experience
Masatoshi Hori1, Tonsok Kim, Hiromitsu Onishi
1Department of Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka 565-0871, Japan. mhori@radiol.med.osaka-u.ac.jp
Purpose:
To compare a three-dimensional (3D) T2-weighted turbo spin-echo (TSE) magnetic resonance (MR) sequence (VISTA; Philips Medical Systems, Best, the Netherlands) with a two-dimensional (2D) T2-weighted TSE sequence in terms of image quality, signal intensity (SI) difference ratios, conspicuity, and staging of uterine tumors.
Materials And Methods:
This retrospective study was approved by the institutional review board, and informed consent was waived. Sixty-one women (mean age, 53.0 years ± 13.7 [standard deviation]; range, 30-87 years) with cervical carcinoma (n = 28), endometrial carcinoma (n = 21), or leiomyoma (n = 30) of the uterus were included. Patients underwent T2-weighted MR imaging at 3 T with both 1-mm-thick 3D and 5-mm-thick 2D T2-weighted TSE sequences. Three-dimensional T2-weighted TSE images were reconstructed at 5-mm thickness with the aid of a workstation. Quantitative analyses of signal-to-noise ratio (SNR) and SI difference ratios between tumors and other tissues and qualitative analyses of image quality and tissue conspicuity were performed. Two radiologists independently assessed local-regional staging for carcinomas. Quantitative values, qualitative scores, and tumor staging were analyzed by using the paired t test, Wilcoxon signed rank test, and McNemar test, respectively.
Results:
Mean myometrial SNR was higher on 3D than 2D images (14.3 vs 9.8; P < .0001). Mean SI difference ratios between cervical (0.45 vs 0.34; P < .0001) or endometrial (0.46 vs 0.40; P = .044) carcinomas and gluteal muscle were higher on 3D images, but those between leiomyoma and myometrium (0.33 vs 0.43; P < .0001) were lower than those on 2D images. Image quality (P = .0004) and carcinoma conspicuity (P < .0005) were superior with the 3D T2-weighted TSE sequence. Although multiplanar reconstruction of 3D T2-weighted TSE images was useful for staging in one case, there were no significant differences between 3D and 2D T2-weighted TSE imaging in accuracy of staging for the two readers for cervical or endometrial carcinoma.
Conclusion:
The 3D T2-weighted TSE sequence showed certain advantages over the 2D T2-weighted TSE sequence, and it has the potential to improve the performance of MR imaging for the evaluation of uterine carcinoma.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...