Hypertrophic cardiomyopathy: quantification of late gadolinium enhancement with contrast-enhanced cardiovascular MR imaging
Related Experiment Video
Updated: Jun 7, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Caitlin J Harrigan1, Dana C Peters, C Michael Gibson
1PERFUSE Core Laboratories and Data Coordinating Center, Beth Israel Deaconess Medical Center, Harvard Medical School, RW 453 East Campus, 330 Brookline Ave, Boston, MA 02215, USA.
Insights
The 6 SD gray-scale threshold best quantifies late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM) patients, offering high reproducibility. This semiautomated method improves accuracy for LGE assessment in HCM.
Area of Science:
- Cardiology
- Medical Imaging
- Biomedical Engineering
Background:
- Hypertrophic cardiomyopathy (HCM) is a significant cause of sudden cardiac death.
- Accurate quantification of late gadolinium enhancement (LGE) in HCM is crucial for risk stratification.
- Current LGE quantification methods can lack reproducibility.
Purpose of the Study:
- To identify the most reproducible semiautomated gray-scale thresholding technique for quantifying LGE in HCM patients.
- To compare the accuracy and reproducibility of different thresholding methods against visual assessment.
Main Methods:
- 201 patients with HCM underwent LGE cardiovascular magnetic resonance (MR) imaging.
- LGE was quantified using visual assessment and semiautomated gray-scale thresholds (2, 4, 6 SDs above mean, 2 SDs above noise).
- Reproducibility was assessed by repeating measurements and using Bland-Altman analysis and correlation coefficients.
Main Results:
- The 6 SD threshold showed the strongest correlation (r=0.913) with visual LGE assessment.
- This method demonstrated significantly less intraobserver (0.6 g ± 8) and interobserver (5.4 g ± 18) variability compared to visual assessment.
- All tested gray-scale thresholds correlated significantly with visual assessment.
Conclusions:
- Semiautomated LGE quantification using a 6 SD threshold above the mean signal intensity is a reproducible and accurate method for HCM.
- This objective approach closely approximates visual assessment of LGE extent.
- The 6 SD threshold method is recommended for quantifying LGE in clinical practice for HCM patients.
Purpose:
To determine the most reproducible semiautomated gray-scale thresholding technique for quantifying late gadolinium enhancement (LGE) in a large cohort of patients with hypertrophic cardiomyopathy (HCM).
Materials And Methods:
All study patients signed a statement approved by the internal review boards of the participating institutions, agreeing to the use of their medical information for research purposes. LGE cardiovascular magnetic resonance (MR) imaging was performed in 201 patients (71% male) with a mean age of 41.5 years ± 17.6 (standard deviation [SD]) by using standard techniques with administration of 0.2 mmol of gadopentetate dimeglumine per kilogram of body weight. The presence and quantity of LGE were determined first with visual assessment; then with gray-scale thresholds of 2 SDs, 4 SDs, and 6 SDs above the mean signal intensity for the normal remote myocardium; and then with 2 SDs above noise. The LGE quantifications were repeated 4 or more weeks apart to assess reproducibility. Bland-Altman analysis and correlation coefficients were used to compare the visual and various thresholding methods, with normally distributed variables expressed as means ± SDs.
Results:
LGE was identified in 103 (51%) subjects. The mean quantity of LGE at visual analysis was 13 g ± 20 compared with 12 g ± 17 at 6 SDs, 25 g ± 23 at 4 SDs, 55 g ± 31 at 2 SDs, and 64 g ± 69 at 2 SDs above noise. All gray-scale thresholds were significantly correlated with visual assessment. The 6-SD threshold had the strongest correlation (r = 0.913, P < .0001) compared with thresholds of 2 SDs (r = 0.81) and 4 SDs (r = 0.91) above the mean and 2 SDs above noise (r = 0.53) (P < .001 for all comparisons). In addition, compared with visual assessment, the 6-SD threshold yielded less intraobserver variability (difference, 0.6 g ± 8, κ = 0.66 [P < .0001] vs 1.4 g ± 9, κ = 0.49 [P < .0001]) and less interobserver variability (difference, 5.4 g ± 18, κ = 0.20 [P < .0001] vs -18.4 g ± 18, κ = 0.08 [P < .0001]).
Conclusion:
Semiautomated LGE cardiovascular MR gray-scale thresholding with 6 or more SDs above the mean signal intensity for the visually normal remote myocardium yields the closest approximation of the extent of LGE identified with visual assessment and is highly reproducible. This objective method should be considered for quantifying LGE in patients with HCM.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Imaging Studies for Cardiovascular System IV: CMRI
Cardiomyopathy II: Dilated Cardiomyopathy
Mitral Stenosis II: Clinical features and Diagnostic Tests