Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Synergistic surface modification of zirconia nanotubes with silver and hydroxyapatite for enhanced early-stage cytocompatibility: ToF-SIMS insights into fibronectin adsorption.

RSC advances·2026
Same author

Emission Dynamics of Constitutive and Herbivore-induced Plant Volatiles from Norway Maple (Acer platanoides) Trunk Infested by the Asian Longhorned Beetle (Anoplophora glabripennis (Motschulsky)).

Journal of chemical ecology·2026
Same author

Novel Ag-modified zirconia nanomaterials with antibacterial activity.

RSC advances·2026
Same author

Trace-Level Ammonia-Water Interactions in Hydrogen: Challenges in Gas Purity Analysis Using Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS).

ACS measurement science au·2025
Same author

Fast and sustainable active pharmaceutical ingredient (API) screening in over-the-counter and prescription drug products by surface-assisted plasma-based desorption/ionization high-resolution mass spectrometry.

Analytical methods : advancing methods and applications·2025
Same author

Optimized fast gas chromatography coupled with proton-transfer-reaction time-of-flight mass spectrometry for the selective near real-time analysis of herbivore-induced plant volatiles.

Journal of chromatography. A·2025
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 7, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

Inductively coupled plasma mass spectrometry: recent trends and developments.

Carsten Engelhard1

  • 1Institute of Inorganic and Analytical Chemistry, University of Münster, Corrensstr. 30, 48149 Münster, Germany. carsten.engelhard@uni-muenster.de

Analytical and Bioanalytical Chemistry
|November 4, 2010
PubMed
Summary

Inductively coupled plasma mass spectrometry (ICP-MS) is advancing with new instruments enabling simultaneous elemental and speciation analysis. These developments enhance capabilities in nanosciences, medicine, and fast transient signal monitoring.

More Related Videos

In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions
10:22

In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions

Published on: June 16, 2014

Related Experiment Videos

Last Updated: Jun 7, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions
10:22

In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions

Published on: June 16, 2014

Area of Science:

  • Analytical Chemistry
  • Spectrometry
  • Mass Spectrometry

Background:

  • Inductively coupled plasma mass spectrometry (ICP-MS) is entering its fourth decade.
  • ICP-MS technology continues to evolve with significant instrumental advancements.

Purpose of the Study:

  • To review recent trends and developments in ICP-MS.
  • To highlight instrumental innovations and emerging applications in the field.

Main Methods:

  • Review of novel instrumental developments in ICP-MS.
  • Focus on a new mass spectrometer with Mattauch-Herzog geometry and a focal-plane-camera array detector.
  • Discussion of applications in nanosciences and medicine, including direct analysis of microparticles and single cells.

Main Results:

  • A novel mass spectrometer allows simultaneous recording of the full elemental mass range.
  • This enables monitoring of fast transient signals in techniques like chromatography and laser ablation.
  • Instrumental developments facilitate direct analysis of microparticles and single cells for nanomedical applications.

Conclusions:

  • Recent ICP-MS developments offer enhanced capabilities for elemental and speciation analysis.
  • The technology is poised for significant impact in fields such as isotope ratio analysis, nanosciences, and medicine.
  • Simultaneous full mass range detection and single-cell analysis represent key future directions.