Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Superconducting phase diagram of multilayer square-planar nickelates.

Science (New York, N.Y.)·2026
Same author

Disentangling Electronic and Strain Effects in Core-Shell Pd@Pt Catalysts.

Journal of the American Chemical Society·2026
Same author

Nonprecious Core-Shell Catalysts for Durable High-Performance Water Electrolysis.

Journal of the American Chemical Society·2026
Same author

Atomic-Scale Imaging of Lithium Vacancies in a Battery Cathode by Multislice Electron Ptychography.

Nano letters·2026
Same author

Publisher Correction: Theory-driven design of high-valence metal sites for water oxidation confirmed using in situ soft X-ray absorption.

Nature chemistry·2026
Same author

Detective Quantum Efficiency-Based Comparison of HRTEM and Ptychography Phase Imaging.

Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada·2026
Same journal

Near-exceptional point degeneracy enables multilevel optical memory.

Nature nanotechnology·2026
Same journal

Monolithic manufacturing of an electrically addressable quasi-suspended nanophotonic aperture.

Nature nanotechnology·2026
Same journal

Halide-site-substituting spacer creates quasi-two-dimensional perovskites for vapour-deposited light-emitting diodes.

Nature nanotechnology·2026
Same journal

Nanoscale amorphization of poly(triarylamine) for efficient and stable inverted perovskite photovoltaics.

Nature nanotechnology·2026
Same journal

Bridging nanotechnology and mechanobiology.

Nature nanotechnology·2026
Same journal

Coherent 2D/3D van der Waals epitaxy enables single-crystal perovskite heterostructures.

Nature nanotechnology·2026
See all related articles

Related Experiment Video

Updated: Jun 7, 2026

Targeted Studies Using Serial Block Face and Focused Ion Beam Scan Electron Microscopy
09:09

Targeted Studies Using Serial Block Face and Focused Ion Beam Scan Electron Microscopy

Published on: August 10, 2019

Electron microscopy: a new spin on electron beams

Huolin L Xin, David A Muller

    Nature Nanotechnology
    |November 5, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells
    08:29

    Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

    Published on: October 17, 2025

    Related Experiment Videos

    Last Updated: Jun 7, 2026

    Targeted Studies Using Serial Block Face and Focused Ion Beam Scan Electron Microscopy
    09:09

    Targeted Studies Using Serial Block Face and Focused Ion Beam Scan Electron Microscopy

    Published on: August 10, 2019

    Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells
    08:29

    Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

    Published on: October 17, 2025