Summary
The MammoSite balloon brachytherapy clinical target volume (CTV) margin was found to be smaller than expected, treating a smaller effective volume than three-dimensional conformal radiotherapy (3D-CRT) CTVs. This study highlights variability in MammoSite CTV margins.
Area of Science:
- Oncology
- Medical Physics
- Radiotherapy
Background:
- Clinical target volume (CTV) definition for accelerated partial breast irradiation (APBI) varies between balloon brachytherapy (1 cm margin) and three-dimensional conformal radiotherapy (3D-CRT) (1.5 cm margin).
- Previous research suggested equivalence between these CTV margins.
- Deformable registration offers a method to precisely assess treated volumes in radiotherapy.
Purpose of the Study:
- To evaluate the effective clinical target volume (CTV) treated by MammoSite balloon brachytherapy using deformable registration.
- To compare the effective MammoSite CTV with CTVs generated by standard 3D-CRT planning margins.
- To investigate the impact of cavity-balloon conformance on the effective CTV margin.
Main Methods:
- Ten patients treated with MammoSite balloon brachytherapy were retrospectively analyzed.
- Two CT scans (pre- and post-implantation) were obtained for each patient.
- In-house deformable registration software was used to map the MammoSite CTV onto a balloonless CT dataset, with validation using anatomical landmarks.
Main Results:
- The effective MammoSite CTV was, on average, 7% larger than 1 cm 3D-CRT CTVs but 38% smaller than 1.5 cm 3D-CRT CTVs.
- The average effective CTV margin was 1.0 cm, matching the actual MammoSite margin, but was non-uniform, ranging from 5 to 15 mm.
- Poor cavity-balloon conformance resulted in effective margins less than 1 cm; balloon size did not significantly correlate with effective margin.
Conclusions:
- The 1.0-cm MammoSite CTV margin treated a significantly smaller effective volume compared to the 1.5-cm 3D-CRT CTV.
- The effective margin for MammoSite balloon brachytherapy is non-uniform and influenced by cavity-balloon conformance.
- This study suggests a potential discrepancy in target volume coverage between MammoSite and 3D-CRT APBI techniques.