Related Experiment Video
Updated: Jun 7, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Nuclear medicine annual external occupational dose distribution: Rio de Janeiro, Brazil, year 2005
Claudia L P Mauricio1, Ana L S Lima, Herica L R da Silva
1Instituto de Radioproteção e Dosimetria, IRD/CNEN, Av Salvador Allende, Rio de Janeiro, Brazil. claudia@ird.gov.br
Nuclear medicine staff in Rio de Janeiro (RJ) had occupational doses below the annual limit in 2005. However, some professionals received doses over 4.0 mSv, with extremity doses significantly higher than thorax doses, indicating a need for improved radiation safety.
Area of Science:
- Medical Physics
- Occupational Health
- Radiological Protection
Background:
- Brazil has approximately 300 nuclear medicine services (NMS), with 44 located in Rio de Janeiro (RJ).
- Routine external dose monitoring is standard practice for most nuclear medicine personnel.
- The increasing number of professionals and their occupational doses in nuclear medicine necessitates ongoing safety assessments.
Purpose of the Study:
- To statistically analyze the annual external occupational doses for nuclear medicine staff in Rio de Janeiro (RJ) during 2005.
- To evaluate compliance with regulatory dose limits and identify areas for radiation protection improvement.
Main Methods:
- Statistical analysis of annual external occupational doses recorded in 2005 for all RJ NMS.
- Comparison of individual doses against the mean annual dose limit of 20 mSv.
- Analysis of extremity dosemeter usage and extremity-to-thorax dose ratios.
Main Results:
- Approximately 100 professionals in RJ NMS received annual external doses exceeding 4.0 mSv.
- No staff member exceeded the annual dose limit of 20 mSv.
- Extremity doses, measured by dosemeters used by about 10% of staff, were in some cases over 10 times higher than thorax doses, with a maximum ratio of 72:1.
Conclusions:
- While no staff exceeded the annual dose limit, a significant number received doses above 4.0 mSv.
- The high extremity-to-thorax dose ratios highlight potential deficiencies in radiation protection practices for certain procedures.
- There is a clear need to enhance radiation protection strategies in nuclear medicine, particularly concerning extremity dosimetry and monitoring, due to increasing occupational exposures.
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiation: Applications
The average...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Absorption of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET