Discrepancies between two formulations of signal-to-noise ratio for background-limited detection

Applied Optics
|November 6, 2010
PubMed

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Significance Testing: Overview01:04

Significance Testing: Overview

Significance testing is a set of statistical methods used to test whether a claim about a parameter is valid. In analytical chemistry, significance testing is used primarily to determine whether the difference between two values comes from determinate or random errors. The effect of a particular change in the measurement protocol, analyst, or sample itself can cause a deviation from the expected result. In the case of a suspected deviation/outlier, we need to be able to confirm mathematically...
Wald-Wolfowitz Runs Test II01:17

Wald-Wolfowitz Runs Test II

The Wald-Wolfowitz runs test, commonly referred to as the runs test, is a nonparametric test used to assess the randomness of ordered data. The test evaluates the number of runs, which are consecutive sequences of similar elements within the data. If the number of runs is significantly higher or lower than expected, the data is considered non-random, indicating a detectable pattern or structure.
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
¹H NMR Signal Integration: Overview00:58

¹H NMR Signal Integration: Overview

The intensity of a signal, which can be represented by the area under the peak, depends on the number of protons contributing to that signal. The area under each peak is shown as a vertical line called an integral, with the integral value listed under it, as seen in the proton NMR spectrum of benzyl acetate. Each integral value is divided by the smallest integral value to obtain the ratio of the number of protons producing each signal. The ratio reveals the relative number of protons and not...
Sign Test for Matched Pairs01:17

Sign Test for Matched Pairs

The sign test for matched pairs offers a robust method for comparing two paired samples, often for the effects of an intervention in one of them. This method is very useful in situations where the underlying distribution of the data is unknown. The test compares two related samples—often pre- and post-treatment measurements on the same subjects—to determine if there are significant differences in their median values.
To conduct the sign test, we first calculate the differences in value between...