Related Experiment Video
Updated: Jun 7, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Bond strength of soft liners to fiber-reinforced denture-base resin
Lippo V J Lassila1, M Murat Mutluay, Arzu Tezvergil-Mutluay
1Department of Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland.
Purpose:
This study evaluated bond strengths of four soft liners to fiber-reinforced (FR) and unreinforced poly methyl(methacrylate) (PMMA) denture-base resin.
Materials And Methods:
The autopolymerized denture-base resin Palapress Vario (Heraus Kulzer GmbH, Hanau, Germany) was used as the substrate (15 × 15 × 5 mm³). The test group consisted of substrates reinforced with porous PMMA preimpregnated unidirectional glass fibers (Stick [StickTech, Turku, Finland]) (PMMA + FR group), and the control group was unreinforced acrylic resin (PMMA group) (n = 80 per group). One of four soft liners (Ufi Gel SC [Voco, Cuxhaven, Germany], Sofreliner Tough [Tokuyama Dental Corporation, Tokyo, Japan], Vertex SoftSil 25 [Vertex-Dental B.V., Zeist, The Netherlands], and Eversoft [Dentsply Austenal, York, PA]) was placed and cured between two substrates using a polyethylene ring (10 mm inner radius, 3 mm height). Tensile bond strength tests (crosshead speed = 10 mm/min) were performed, and the results were analyzed using analysis of variance followed by Tukey's test (p= 0.05). Fracture surfaces were categorized as adhesive or cohesive-mixed modes, and failure types were statistically analyzed using chi-square test.
Results:
FR did not affect the bond strength results significantly (p > 0.05) except for Ufi Gel SC. Significant differences in bond strength were found among the reline materials (p < 0.001). FR specimens showed a significantly higher number of cohesive-mixed fractures compared to unreinforced specimens (p < 0.05), except for plasticized acrylic-based reline material (Eversoft [Dentsply Austenal]), which showed fewer cohesive-mixed failures with FR.
Conclusions:
The choice of appropriate reline material system with FR acrylic resin is important for the soft liner/denture-base polymer bond. Glass FR did not have a decreasing effect on the bond strength, except for Ufi Gel SC.
Related Concept Videos
Bonding and Strength of Aggregate
Mortar Properties
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...