Cardiac output monitoring: is there a gold standard and how do the newer technologies compare?
1Beth Israel Deaconess Medical Center, Boston, MA, USA.
Abstract:
As a principal determinant of oxygen delivery and of blood pressure, cardiac output (CO) represents an important hemodynamic variable. Its accurate measurement, therefore, is important to the clinician caring for critically ill patients in a variety of care environments. Though the first clinical measurement of CO occurred 70 years ago, it was the introduction of the pulmonary artery catheter (PAC) with thermodilution-based determination of CO in the 1970s that set the stage for practical and widespread clinical measurement of CO. Although the usefulness and accuracy of this technique have justified its consideration as a "practical" gold standard in CO measurement, its drawbacks have driven the search for newer, less invasive measurement techniques. The last decade has seen the introduction of several such devices into the clinical arena. This article will serve to give a brief review of the history of CO measurement, to provide a discussion of the measurement of accuracy as it relates to CO measurement, and to discuss some of the newer methods and devices for CO measurement and how they have fared against a "practical" gold standard.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...