Related Experiment Video
Updated: Jun 6, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Mo/Si multilayer-coated ruled blazed gratings for the soft-x-ray region
Abstract:
Two Mo/Si multilayer-coated blazed gratings have been fabricated for operation at soft-x-ray wavelengths above the Si L edge, λ ≥ 12.4 nm, at (near) normal incidence. The sawtooth profile of the grating structure was mechanically ruled into a 200-nm Au film that was deposited onto a plane glass substrate. To smooth the rough Au surface and to prevent interdiffusion of the Au film with the upper Mo/Si multilayer, a carbon film was evaporated onto the Au grating surface of one of the gratings before the deposition of the multilayer coating. We matched the multilayer grating, working on blaze in the third diffraction order, in which an absolute diffraction efficiency of 3.4% at a wavelength of 14 nm was measured, whereas only 1.1% was achieved for a similar grating (without a carbon interlayer). These efficiencies are higher than those obtained for other ruled blazed gratings reported in the literature. As a result of the multilayer and grating periodicity, the wavelength of diffraction can be tuned bya rotation of the grating, which is important for application in a soft-x-ray monochromator.
More Related Videos
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...