Transmission of light through right-angle corners in hollow light guides

Applied Optics
|November 10, 2010
PubMed

Related Concept Videos

Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Thin-Walled Hollow Shafts01:15

Thin-Walled Hollow Shafts

In analyzing a thin-walled hollow shaft subjected to torsional loading, a segment with width dx is isolated for examination. Despite its equilibrium state, this segment faces torsional shearing forces at its ends. These forces are quantitatively described by the product of the longitudinal shearing stress on the segment's minor surface and the area of this surface, leading to the concept of shear flow. This shear flow is consistent throughout the structure, indicating a uniform distribution of...
Sight Distance in a Vertical Curve01:29

Sight Distance in a Vertical Curve

Sight distance on vertical curves is critical in roadway design. It ensures drivers can see far enough ahead to identify and respond to hazards effectively. This directly impacts safety, driver comfort, and the overall efficiency of the transportation network.Vertical curves are classified into crest and sag curves based on their geometry. For crest curves, sight distance is determined by the line of sight between a driver's eye and a small object on the road's surface. Design parameters for...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
Optimization Problems01:26

Optimization Problems

Optimization problems often involve identifying maximum or minimum values under specific constraints. A well-known example is determining the longest horizontal pipe that can be moved around a right-angled corner, where a 3-meter-wide hallway meets a 2-meter-wide hallway. This scenario, common in architectural design and industrial transport, can be understood conceptually through geometric and trigonometric reasoning.To visualize the problem, consider the pipe as a straight line that touches...