Abstract:
Common-path interferometers have been used to perform phase visualization for over 40 years. A number of techniques have been proposed, including dark central ground, phase contrast (π/2 and π), and field-absorption interferometers. The merits of the interferometers have been judged ad hoc by either tests with a small number of phase objects or by computer simulation. Three standardized criteria, which consolidate the work of others, are proposed to evaluate common-path interferometers: fringe visibility, fringe irradiance, and fringe accuracy. The interferometers can be described as one generic class of Fourier-plane filters and can be analyzed for all input conditions. Closed-form expressions are obtained for visibility and irradiance under the forced condition that little inaccuracy is tolerated. This analysis finds that the π-phase-contrast interferometer is a good choice if the optical phase disturbance is at least 2π; for smaller disturbances, the Π/2 filter selected by Zernike is near optimum. It is shown mathematically that the resulting fringe visibility is highly object dependent, and good results are not ensured. By allowing the optical beam to be 50% larger than the phase object, the interferometer performs well under all conditions. With this approach and a combination π-phase/field-absorption filter, interference fringe visibility is greater than 0.8 for all phase objects.
Related Concept Videos
Interference and Diffraction
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
IR Spectrometers
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...