[The arterial-end tidal CO2 partial pressure difference during anesthesia]
Related Experiment Video
Updated: Nov 6, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Abstract:
Arterial CO2 partial pressure (PaCO2) can be continuously and noninvasively estimated by monitoring end-tidal CO2 partial pressure (PetCO2). However, the difference between the two (P(a-et)CO2) may vary considerably between patients. In 26 patients undergoing general anesthesia for various surgical procedures, P(a-et)CO2 was measured. We tested the hypothesis that certain clinical characteristics are associated with higher P(a-et)CO2 values in a given patient. In addition, we tested the hypothesis that P(a-et)CO2 remains constant during anesthesia by comparing the mean of eight P(a-et)CO2 values, which were measured at 15-min intervals, with the initial (P(a-et)CO2 value. Impaired lung function, defined as a lung score above 6, age above 50 years, and overweight (defined as greater than 120% of ideal body weight) were associated with increased P(a-et)CO2 (mean +/- SD: 6.27 +/- 1.85; 5.27 +/- 2.11; and 6.19 +/- 1.95 mmHg respectively) when compared to normal lung function (lung score less than or equal to 6), age below 50 years, and normal weight (less than 120% of ideal body weight, 3.87 +/- 2.31; 3.55 +/- 2.58; and 3.77 +/- 2.25 respectively). Although these differences are statistically significant, the standard deviations are large and do not allow the prediction of P(a-et)CO2 in a given patient. Initial P(a-et)CO2 correlated well with subsequent P(a-et)CO2 (R = 0.91, P less than 0.001). The mean difference of the subsequent P(a-et)CO2 values from the initial values was 0.05 +/- 0.80 mmHg (mean +/- SD) and was not significantly different from zero. In the patient population studied, P(a-et)CO2 thus remained generally constant during anesthesia.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:41Hypercapnic Hyperventilation to Accelerate Emergence from Inhaled Volatile Anesthetics: A Practical Method Using Standard Hospital Equipment
Published on: June 26, 2026
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Stages of General Anesthesia
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...