Evaluation of oxygen delivery in a patient with Berlin ExcorTM biventricular support
N Siegenthaler1, R Giraud, K Bendjelid
1Intensive Care Division, Geneve University Hospitals, Geneve, Switzerland.
Abstract:
After the implantation of a biventricular assist device hemodynamic evaluation is difficult. The device itself frequently does not report the real outflow as it does not take into account the native cardiac output. Other methods used for cardiac output measurements cannot be employed for technical reasons and/or because their measurements could be misleading. The consequences are twofold; firstly, cardiac output cannot be estimated with accuracy. Secondly, the adequacy of oxygen supply and demand cannot be assessed. In order to monitor the adequacy of cardiac output in patient with Berlin heart biventricular support, the authors propose an original non invasive method to measure mixed venous blood saturation.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...