Focal switch: a new effect in low-Fresnel-number systems
Applied Optics
|November 12, 2010
Abstract:
It is shown for the first time we believe, that when a spherical wave illuminates a certain type of diffracting screen, in addition to the expected focal-shift effect, depending on the value of the Fresnel number of the focusing system, a focal switch effect can appear, i.e., an increase in the height of the lateral lobe of the axial-intensity distribution over that of the central lobe.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Focusing of Light in the Eye
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Field Effect Transistor
Field-effect transistors (FETs) are integral to electronic circuits and distinguished by their three-terminal setup: the gate, drain, and source. These transistors operate as unipolar devices, which utilize either electrons or holes as charge carriers, in contrast to bipolar transistors, which use both types of carriers. The primary function of the FET is to modulate the flow of these carriers from the source to the drain through a channel. The voltage difference between the gate and source...