Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors
O Gosling1, R Loader, P Venables
1Plymouth Hospitals NHS Trust, Derriford Hospital, Plymouth, Devon, UK. Oliver.gosling@pms.ac.uk
Aim:
To calculate the effective dose from cardiac multidetector computed tomography (MDCT) using a computer-based model utilizing the latest International Commission on Radiation Protection (ICRP) 103 tissue-weighting factors (2007), to compare this dose with those calculated with previously published chest conversion factors and to produce a conversion factor specific for cardiac MDCT.
Materials And Methods:
An observational study of 152 patients attending for cardiac MDCT as part of their usual clinical care in a university teaching hospital. The dose for each examination was calculated using the computer-based anthropomorphic ImPACT model (the imaging performance assessment of CT scanners) and this was compared with the dose derived from the dose-length product (DLP) and a chest conversion factor.
Results:
The median effective dose calculated using the ImPACT calculator (4.5 mSv) was significantly higher than the doses calculated with the chest conversion factors (2.2-3 mSv).
Conclusion:
The use of chest conversion factors significantly underestimates the effective dose when compared to the dose calculated using the ImPACT calculator. A conversion factor of 0.028 would give a better estimation of the effective dose from prospectively gated cardiac MDCT.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...