Related Experiment Video
Updated: Jun 6, 2026

Detection and Genogrouping of Noroviruses from Children's Stools By Taqman One-step RT-PCR
Published on: July 22, 2012
Analytical performance of norovirus real-time RT-PCR detection protocols in Canadian laboratories
Kirsten Mattison1, Elsie Grudeski, Brian Auk
1Bureau of Microbial Hazards, Health Canada, Ottawa, ON, Canada.
Background:
Noroviruses (NoVs) are the leading cause of infectious gastroenteritis worldwide. Real-time reverse transcription PCR (real-time RT-PCR) is the preferred method of NoV detection for the majority of testing laboratories. Although the accepted target region for molecular detection assays is the conserved ORF1/ORF2 junction, multiple variations have been published with differences in primers, probes, reagents, multiplexing, etc.
Objectives:
We assessed the detection limit for GII.4 NoV real-time RT-PCR assays as well as the ability to detect the non-GII.4 NoV genotypes in each participating laboratory.
Study Design:
A panel of 25 RNA samples was circulated to 18 testing laboratories for comparison of their real-time RT-PCR procedures for NoV detection.
Results:
Multiple protocols with slight differences in reagents or conditions successfully detected 10 genome equivalents or fewer of NoV per reaction. Multiplex procedures were significantly associated (p=0.04) with false negative results, particularly for a GI.2 strain. Sensitive detection was associated with false positive results (p=0.03).
Conclusions:
Overall, the data indicate that comparable results are produced under slightly different assay conditions.