Related Concept Videos

Absorption of Radiation01:05

Absorption of Radiation

The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
Atomic Spectroscopy: Effects of Temperature01:27

Atomic Spectroscopy: Effects of Temperature

Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation01:43

Thermosensation

Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-repetition-rate interferometric Rayleigh scattering for flow-velocity measurements.

Applied physics. B, Lasers and optics·2020
Same author

Direct measurements of collisional Raman line broadening in the S-branch transitions of CO perturbed by CO, N<sub>2</sub>, and CO<sub>2</sub>.

Applied optics·2019
Same author

Direct measurement of CO<sub>2</sub>S-branch Raman linewidths broadened by O<sub>2</sub>, Ar, and C<sub>2</sub>H<sub>4</sub>.

Applied optics·2019
Same author

Quantitative fuel-to-air ratio determination for elevated-pressure methane/air flames using chemiluminescence emission.

Applied optics·2019
Same author

Tracer-free liquid-vapor imaging using lifetime-filtered planar laser-induced fluorescence.

Optics letters·2019
Same author

Quantitative femtosecond, two-photon laser-induced fluorescence of atomic oxygen in high-pressure flames.

Applied optics·2019

Related Experiment Video

Updated: Jun 6, 2026

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
08:52

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere

Published on: April 30, 2018

Selection of multiple optimal absorption transitions for nonuniform temperature sensing.

Lin Ma1, Xuesong Li, Weiwei Cai

  • 1Department of Mechanical Engineering, Clemson University, Clemson, South Carolina 29634, USA. LinMa@clemson.edu

Applied Spectroscopy
|November 16, 2010
PubMed
Summary

This study introduces a new method for selecting optimal spectral transitions in absorption spectroscopy sensors. This technique accurately measures nonuniform temperature distributions, improving sensor design for various applications.

More Related Videos

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
07:38

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared

Published on: January 10, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

Related Experiment Videos

Last Updated: Jun 6, 2026

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
08:52

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere

Published on: April 30, 2018

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
07:38

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared

Published on: January 10, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

Area of Science:

  • Spectroscopy
  • Sensor Technology
  • Optical Engineering

Background:

  • Selecting optimal spectral transitions is critical for designing absorption spectroscopy sensors.
  • Existing methods are limited to uniform temperature distributions and selecting only two transitions.
  • Accurate temperature measurement is essential in many industrial and scientific applications.

Purpose of the Study:

  • To develop a novel method for selecting multiple optimal spectral transitions.
  • To enable the measurement of nonuniform temperature distributions using absorption spectroscopy.
  • To overcome the limitations of previous transition selection methods.

Main Methods:

  • Development of a generalized method for selecting multiple optimal spectral transitions.
  • Validation of the method through numerical simulations.
  • Experimental verification of the proposed method's efficacy.

Main Results:

  • The new method successfully identifies multiple optimal transitions for nonuniform temperature measurements.
  • Numerical tests confirmed the method's accuracy and applicability.
  • Experimental results validated the practical performance of the developed technique.

Conclusions:

  • The proposed method expands the capabilities of absorption spectroscopy sensors.
  • It is applicable to more general cases, including nonuniform temperature distributions.
  • This approach is expected to advance the design of multispectral absorption spectroscopy sensors.