Effects of the levonorgestrel-releasing intrauterine system on cervical mucus quality and sperm penetrability
Related Experiment Video
Updated: Jun 6, 2026

Fluorimetric Techniques for the Assessment of Sperm Membranes
Published on: November 28, 2018
Radha A Lewis1, Deshawn Taylor, Melissa F Natavio
1LAC+USC Medical Center, Los Angeles, CA 90033, USA. radhalewis@yahoo.com
Background:
In levonorgestrel intrauterine system (LNG-IUS) users, the prevention of sperm penetration through cervical mucus has not been demonstrated.
Study Design:
Subjects were enrolled in an investigator-blinded study to compare quality and sperm penetrability of mid-cycle cervical mucus between LNG-IUS users and hormone-free controls. Cervical mucus was microscopically examined using World Health Organization (WHO) cervical mucus analysis (CMA). CMA score ≥10 of 15 points indicated cervical mucus favoring sperm penetration. Mucus was incubated with sperm using the WHO simplified slide test (SST) and Kremer sperm cervical mucus penetration test (SCMPT).
Results:
Data from 14 LNG-IUS users and 16 controls showed 14% of LNG-IUS users had CMA score ≥10% vs. 69% of controls (p=.004). SST showed no sperm penetration for LNG-IUS users, significantly less than controls (0% vs. 64.3%, p<.001). SCMPT demonstrated no sperm mucus penetration for LNG-IUS users at 2 and 6 h (0% vs. 85% in controls with 2-h score ≥6, p<.001; 6 h 0% vs. 79% in controls, p<.001).
Conclusions:
Mid-cycle cervical mucus of LNG-IUS users is poor quality and prevents endocervical sperm transport in vitro.