Effect of some curing methods on acrylic maxillary denture base fit
Fazal Ghani1, Masahiko Kikuchi, Christopher D Lynch
1Cardiff University School of Dentistry, Heath Park.
The European Journal of Prosthodontics and Restorative Dentistry
|November 17, 2010
Summary
This study compared four acrylic denture base processing methods. Microwave-cured denture bases showed the greatest fit-loss, especially in the palate, highlighting the importance of technique selection for complete dentures.
Area of Science:
- Dentistry
- Biomaterials Science
- Prosthodontics
Background:
- Complete dentures are crucial for edentulous patients.
- The fit of denture bases significantly impacts patient comfort and function.
- Various processing techniques exist for acrylic denture bases, each with potential effects on dimensional accuracy.
Purpose of the Study:
- To evaluate and compare the marginal fit of acrylic maxillary denture bases processed using four distinct methods: microwave, quick-wet-heat, slow-wet-heat, and self-curing.
- To quantify the discrepancy between the denture base and the master cast for each processing technique.
- To identify which processing method yields the most accurate fit for complete maxillary dentures.
Main Methods:
- Forty stone casts of an edentulous maxilla were used.
- Acrylic resin patterns were processed into denture bases using four methods: microwave, quick-wet-heat, slow-wet-heat, and self-curing (10 bases per group).
- Denture base fit was assessed by measuring the discrepancy against the cast using silicone wafers.
Main Results:
- Significant variations in fit discrepancies were observed both within and between the different processing groups.
- The palatal region exhibited a proportionally greater fit-loss compared to the sulcular areas across all tested materials (p < 0.05).
- Microwave-cured denture bases demonstrated a greater degree of fit-loss than those processed by the other methods.
Conclusions:
- The choice of processing technique significantly influences the marginal fit of acrylic maxillary denture bases.
- Microwave curing appears to be associated with greater fit discrepancies, particularly in the palatal region.
- Clinicians must carefully select appropriate denture base materials and processing techniques to ensure optimal fit and function for edentulous patients.